Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/jhpadmin/public_html/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the wordpress-seo domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/jhpadmin/public_html/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the custom-facebook-feed domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/jhpadmin/public_html/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the instagram-feed domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/jhpadmin/public_html/wp-includes/functions.php on line 6114
Industrial Pumps in Utica MN

Centrifugal Pumps in Utica, MN

Utica, MN Air-Operated Diaphragm Chemical Pumps and Their Applications

Utica, MN Air-Operated Diaphragm Chemical Pumps and Their Applications

An Air Operated Diaphragm Chemical Pump is a type of positive displacement pump that uses a combination of compressed air and an elastic diaphragm to move chemical liquids. This type of pump is often used in industrial settings, such as chemical processing plants and water treatment facilities, due to its ability to handle high flow rates and corrosive materials. It’s also known for its superior design, as it can run dry without causing damage, making it more reliable than other types of pumps.

These pumps are highly versatile and have a wide range of applications. They are often used in the chemical, pharmaceutical, and food industries, as well as in industrial, agricultural, and water treatment operations. Air Operated Diaphragm Chemical Pumps can be used to transfer, meter, or dispense low to high-viscosity fluids and chemicals while providing precise, accurate flow rates with minimal maintenance.

Utica Air-Operated Diaphragm Chemical Pump Designs & Their Advantages

Utica Air-Operated Diaphragm Chemical Pump Designs & Their Advantages

Fluid-handling devices that employ air pressure to transfer fluids include air operated diaphragm chemical pumps. They are available in several designs, including single- and double-diaphragm models, ball valve layouts, and nonmetallic wetted component setups. These pumps are adaptable and reasonably priced. They can tolerate caustic or abrasive fluids, have high flow rates, and can prime themselves.

They can be used even if the liquid levels change because they are self-priming and can run dry without causing damage. Additionally, they require relatively little maintenance and can deliver a constant flow rate. Last but not least, because these pumps are air-operated, they are simple to install and use a small amount of electricity.

Choosing the Correct Drum Pump in Utica MN

When selecting the ideal drum pump for a specific use, there are several factors that should be taken into account. These factors include:

  • Safety considerations: Pick a pump that complies with applicable safety regulations and is suitable for the unique dangers prevalent in your application. Make sure the pump is explosion-proof, for instance, if you are transporting explosive liquids.
  • Price: Establish your spending limit and select a pump that satisfies your requirements at a cost you are comfortable paying.
  • Volume and flow rate: Consider both the volume and flow rate of the liquid you need to move. Ensure that the drum pump you select has a flow rate that meets your requirements.
  • Power source: Choose a pump that will meet the demands of your application and the type of power source you have available.
  • Compatibility with the medium being transferred: Different models of drum pumps are specifically designed to handle different types of liquids. It is crucial to select the pump that is compatible with the type of liquid you need transported, as some liquids or chemicals can be too abrasive or viscous to work with certain models.
  • Size and weight: Take into account the size and weight of both the pump and the drum or other container from which you will be transferring the liquid. Verify that the pump can fit inside the drum and is not too heavy to handle.
Choosing the Correct Drum Pump in Utica MN

Small Centrifugal Pumps in Utica, MN

High flow rates and capacity to handle large volumes of fluid!

Utica, MN Drum Pump Accessories

  • Cycle Counter - The FTI Air Cycle Counter is an electronic device that counts pump cycles by detecting the presence of the valve carrier. The cycle counter can be universally used on any new or existing FTI Air pump with the proper air valve components.
  • Filter/Regulator - Compact, integrated design saves space and reduces piping, includes dual scale psi/Bar gage. Filters incoming air to five microns. Regulator adjusts air pressure from 7.3 to 120 psi (.5 to 8.3 bar).
  • Liquid Level Control - The FTI Liquid Level Control is a pneumatic/mechanical device that will automatically turn the pump on and off as the liquid level changes
  • SPILLSTOP - Fully pneumatic system safely captures leaked product due to diaphragm failure and automatically shuts down failed pumps to eliminate costly product loss and prevent hazardous spills.
  • Pulsation Dampeners - Removes virtually all hydraulic shock while producing a near steady flow of fluid. Protect piping, valves and fittings from destructive pulsations and surges. Available in a wide range of materials of construction
  • AODDampener - AODDampener is unique pulsation dampener manufactured from 316L stainless steel with PTFE backed diaphragm, has fully automatic air control and handles a wide variety of applications.
Utica, MN Drum Pump Accessories
Utica CENTRIFUGAL PUMPS

MSDB SERIES - MAGNETIC DRIVE, SEALLESS, Utica CENTRIFUGAL PUMPS

  • High power neodymium magnetic drive system handles high specific gravity fluids
  • Two stage versions contain two impellers, three stage versions contain three impellers
  • High specific gravity handling – over 1.8
  • Horizontal or vertical (with IEC motor only) installation
  • Maximum working pressure up to 135 PSI (9.3 bar)
  • Sealless design improves reliability with no seal maintenance to perform or seal leaks
  • Engineered for corrosive fluids with polypropylene/Ryton© or PVDF/Ryton© construction
  • Minimum flow rate is 1 gpm (.23m3/h)
  • Heads up to 300 feet (91.5m)
  • Compact close-coupled design
0 Item | $0.00
View Cart
Call Now Button