Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/jhpadmin/public_html/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the wordpress-seo domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/jhpadmin/public_html/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the custom-facebook-feed domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/jhpadmin/public_html/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the instagram-feed domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/jhpadmin/public_html/wp-includes/functions.php on line 6114
Industrial Pumps in New Pine Creek OR

Industrial Chemical Pumps in New Pine Creek, OR

New Pine Creek CENTRIFUGAL PUMPS

MSDB SERIES - MAGNETIC DRIVE, SEALLESS, New Pine Creek CENTRIFUGAL PUMPS

  • Minimum flow rate is 1 gpm (.23m3/h)
  • Sealless design improves reliability with no seal maintenance to perform or seal leaks
  • Maximum working pressure up to 135 PSI (9.3 bar)
  • Horizontal or vertical (with IEC motor only) installation
  • Two stage versions contain two impellers, three stage versions contain three impellers
  • High specific gravity handling – over 1.8
  • Heads up to 300 feet (91.5m)
  • Engineered for corrosive fluids with polypropylene/Ryton© or PVDF/Ryton© construction
  • High power neodymium magnetic drive system handles high specific gravity fluids
  • Compact close-coupled design

Drum Pumps in New Pine Creek, OR

For transfering and dispensing fluids.

New Pine Creek Air-Operated Diaphragm Chemical Pump Designs & Their Advantages

New Pine Creek Air-Operated Diaphragm Chemical Pump Designs & Their Advantages

Fluid-handling devices that employ air pressure to transfer fluids include air operated diaphragm chemical pumps. They are available in several designs, including single- and double-diaphragm models, ball valve layouts, and nonmetallic wetted component setups. These pumps are adaptable and reasonably priced. They can tolerate caustic or abrasive fluids, have high flow rates, and can prime themselves.

They can be used even if the liquid levels change because they are self-priming and can run dry without causing damage. Additionally, they require relatively little maintenance and can deliver a constant flow rate. Last but not least, because these pumps are air-operated, they are simple to install and use a small amount of electricity.

Practical Applications for Drum Pumps in New Pine Creek, OR

Practical Applications for Drum Pumps in New Pine Creek, OR

  • Construction: To transport construction materials like concrete and grout, drum pumps can be used.
  • Manufacturing: Fluids like coolants, lubricants, and cleaning agents are transferred using drum pumps in manufacturing settings.
  • Drum pumps are used in the mining sector to move fluids like chemicals and water.
  • Water treatment: In water treatment facilities and other locations where clean water is required, drum pumps are used to move water and other fluids.
  • Drum pumps are used in power generation facilities, such as nuclear power plants and coal-fired power plants, to move fluids.
  • Agriculture: Drum pumps are used to deliver water and other fluids to plants and crops.
  • Gasoline production: The oil and gas industry uses drum pumps to transport fluids like oil.
  • Chemical processing: Drum pumps are used to move chemicals in a range of chemical processing applications, such as the manufacture of personal care products, food processing, and pharmaceuticals.

Choosing the Correct Drum Pump in New Pine Creek OR

When selecting the ideal drum pump for a specific use, there are several factors that should be taken into account. These factors include:

  • Volume and flow rate: Consider both the volume and flow rate of the liquid you need to move. Ensure that the drum pump you select has a flow rate that meets your requirements.
  • Safety considerations: Pick a pump that complies with applicable safety regulations and is suitable for the unique dangers prevalent in your application. Make sure the pump is explosion-proof, for instance, if you are transporting explosive liquids.
  • Power source: Choose a pump that will meet the demands of your application and the type of power source you have available.
  • Size and weight: Take into account the size and weight of both the pump and the drum or other container from which you will be transferring the liquid. Verify that the pump can fit inside the drum and is not too heavy to handle.
  • Compatibility with the medium being transferred: Different models of drum pumps are specifically designed to handle different types of liquids. It is crucial to select the pump that is compatible with the type of liquid you need transported, as some liquids or chemicals can be too abrasive or viscous to work with certain models.
  • Price: Establish your spending limit and select a pump that satisfies your requirements at a cost you are comfortable paying.
Choosing the Correct Drum Pump in New Pine Creek OR

New Pine Creek, OR Drum Pump Accessories

  • Pulsation Dampeners - Removes virtually all hydraulic shock while producing a near steady flow of fluid. Protect piping, valves and fittings from destructive pulsations and surges. Available in a wide range of materials of construction
  • Liquid Level Control - The FTI Liquid Level Control is a pneumatic/mechanical device that will automatically turn the pump on and off as the liquid level changes
  • SPILLSTOP - Fully pneumatic system safely captures leaked product due to diaphragm failure and automatically shuts down failed pumps to eliminate costly product loss and prevent hazardous spills.
  • Cycle Counter - The FTI Air Cycle Counter is an electronic device that counts pump cycles by detecting the presence of the valve carrier. The cycle counter can be universally used on any new or existing FTI Air pump with the proper air valve components.
  • AODDampener - AODDampener is unique pulsation dampener manufactured from 316L stainless steel with PTFE backed diaphragm, has fully automatic air control and handles a wide variety of applications.
  • Filter/Regulator - Compact, integrated design saves space and reduces piping, includes dual scale psi/Bar gage. Filters incoming air to five microns. Regulator adjusts air pressure from 7.3 to 120 psi (.5 to 8.3 bar).
New Pine Creek, OR Drum Pump Accessories
0 Item | $0.00
View Cart
Call Now Button